GN 012.53 - Weld Root Reinforcement and Overlap
- Details
- Category: Use & In-Service Inspection
APEK - AICIP GUIDANCE NOTE |
SIGNS OR INDICATIONS IN IN-SERVICE WELD ROOT REINFORCEMENT AND OVERLAP |
APEK GN 012.53 Rev 1 |
1 Figure |
|
2 PE involved |
New vertical oil separator – Carbon steel, Class 3 pressure vessel 9mm thick, 500mm OD. Imported ASME VIII-1 ŋ=70% ie no NDT. |
3 Sign(s) |
Root penetration (2.5mm continuous); overlap (2mm – continuous, both sides); minor spatter from circumferential weld. |
4 Location of Signs |
Inside vessel on vertical weld. |
5 When & Where occurred |
Overseas; 2014. |
6 Detection & Investigation |
During commissioning inspection in Australia by VT using endoscope via 50mm nozzle. Various standards reviewed. A joggled joint with the equivalent of overlap is permitted for circumferential joints. |
7 Failure mode(s) (damage mechanisms) |
Failure to comply with AS 4037 ie Weld overlap is DNC (to AS4037). Overlap not referenced in ASME VIII-1 – inspector accepted. Reinforcement - ok. |
8 Most probable causes |
Poor fitting backing bar (eg Copper) for small diameter vessel. |
9 Outcome |
Investigation was required. Put into service without removal on basis: |
10 Fix |
No correction was required. |
11 Possible Prevention |
Better shaped backing bar, edge bending, or clamping. |
12 Frequency |
Rare (most inspectors did not recognise). |
13 Lesson |
.1 Although it may be DNC, consider if fit for service and the risk for the owner/user. |
Notes:
- Overlap would not be acceptable for severe corrosion service or where hygiene is critical as for food or medical use.
- Defect criteria may differ from the original code provided it is assessed, shown to be fit for the particular service, is documented and acceptable to the owner/user.
SA